Buildings, Size and Age Data by Equipment Types for Office Buildings
| |
Number
of Buildings (thousand) |
Percent
of Buildings |
Floorspace
(million square feet) |
Percent
of Floorspace |
Square
Feet per Building (thousand) |
Median
Age of Building (years) |
| |
| |
|
|
|
|
|
|
| All
Office Buildings |
739 |
100 |
12,044 |
100 |
16.3 |
24.5 |
| |
|
|
|
|
|
|
| Heating
Equipment (more than one may apply) |
|
|
|
|
|
|
| Heat
Pumps |
139 |
19 |
1,949 |
16 |
14 |
17.5 |
| Furnaces |
236 |
32 |
1,807 |
15 |
7.7 |
27.5 |
| Individual
Space Heaters |
135 |
18 |
2,631 |
22 |
19.5 |
39.5 |
| District
Heat |
19 |
3 |
1,487 |
12 |
76.3 |
42.5 |
| Boilers |
105 |
14 |
4,211 |
35 |
40 |
33.5 |
| Packaged
Heating Units |
275 |
37 |
4,304 |
36 |
15.7 |
22.5 |
| Other |
13 |
2 |
1,244 |
10 |
92.9 |
15.5 |
| |
|
|
|
|
|
|
| Main
Heating Equipment |
|
|
|
|
|
|
| Heat
Pumps |
115 |
16 |
1,068 |
9 |
9.3 |
15.5 |
| Furnaces |
219 |
30 |
1,317 |
11 |
6 |
29.5 |
| Individual
Space Heaters |
19 |
3 |
313 |
3 |
16.5 |
31.5 |
| District
Heat |
17 |
2 |
1,321 |
11 |
75.5 |
40.5 |
| Boilers |
94 |
13 |
3,758 |
31 |
39.8 |
37.5 |
| Packaged
Heating Units |
257 |
35 |
3,115 |
26 |
12.1 |
22.5 |
| Other
|
7 |
1 |
917 |
8 |
130.8 |
17.5 |
| |
|
|
|
|
|
|
| Cooling
Equipment (more than one may apply) |
|
|
|
|
|
|
| Residential-Type
Central Air Conditioners |
137 |
18 |
1,089 |
9 |
8 |
18.5 |
| Heat
Pumps |
141 |
19 |
2,158 |
18 |
15.3 |
20.5 |
| Individual
Air Conditioners |
90 |
12 |
1,500 |
12 |
16.7 |
50.5 |
| District
Chilled Water |
6 |
1 |
678 |
6 |
106.7 |
36.5 |
| Central
Chillers |
31 |
4 |
4,559 |
38 |
146.7 |
28.5 |
| Packaged
Air Conditioning Units |
385 |
52 |
6,838 |
57 |
17.8 |
24.5 |
| Swamp
Coolers |
5 |
1 |
169 |
1 |
33.6 |
22.5 |
| Other |
14 |
2 |
565 |
5 |
Q |
33.5 |
| |
|
|
|
|
|
|
| Main
Cooling Equipment |
|
|
|
|
|
|
| Residential
Type A/C Units |
131 |
18 |
698 |
6 |
5.3 |
18.5 |
| Heat
Pumps |
114 |
15 |
1,009 |
8 |
8.9 |
20.5 |
| Individual
Air Conditioners |
62 |
8 |
463 |
4 |
7.5 |
50.5 |
| District
Chilled Water |
5 |
1 |
589 |
5 |
111.6 |
32.5 |
| Central
Chillers |
28 |
4 |
4,181 |
35 |
150.1 |
28.5 |
| Packaged
A/C Units |
369 |
50 |
4,553 |
38 |
12.3 |
23.5 |
| Swamp
Coolers |
Q |
Q |
Q |
Q |
Q |
64.5 |
| Other
|
Q |
Q |
267 |
2 |
45.8 |
16.5 |
| |
|
|
|
|
|
|
| Main
Equipment Replaced Since 1995 (more than one may apply) |
|
|
|
|
|
|
| Heating
|
179 |
24 |
1,972 |
16 |
11 |
31.5 |
| Cooling |
196 |
27 |
2,851 |
24 |
14.5 |
28.5 |
| |
|
|
|
|
|
|
| Lighting
Equipment Types (more than one may apply) |
|
|
|
|
|
|
| Incandescent
|
362 |
49 |
7,598 |
63 |
21 |
31.5 |
| Standard
Fluorescent |
696 |
94 |
11,608 |
96 |
16.7 |
24.5 |
| Compact
Fluorescent |
131 |
18 |
5,844 |
49 |
44.4 |
23.5 |
| High
Intensity Discharge |
39 |
5 |
2,946 |
24 |
74.6 |
28.5 |
| Halogen |
81 |
11 |
4,034 |
33 |
49.5 |
22.5 |
| Other
|
Q |
Q |
Q |
Q |
Q |
12.5 |
| |
|
|
|
|
|
|
| Water
Heating Equipment |
|
|
|
|
|
|
| Centralized
System |
426 |
58 |
6,184 |
51 |
14.5 |
27.5 |
| Distributed
System |
156 |
21 |
2,186 |
18 |
14 |
21.5 |
| Combination
of Centralized and Distributed System |
33 |
4 |
2,502 |
21 |
75.8 |
22.5 |
| |
|
|
|
|
|
|
| Commercial
Refrigeration Equipment (more than one may apply) |
|
|
|
|
|
|
| Any
Equipment |
26 |
4 |
3,331 |
28 |
126.5 |
19.5 |
| Walk-In
Units |
17 |
2 |
2,350 |
20 |
134.5 |
16.5 |
| Cases
or Cabinets |
17 |
2 |
3,074 |
26 |
178.7 |
24.5 |
| None
|
712 |
96 |
8,713 |
72 |
12.2 |
25.5 |
| |
|
|
|
|
|
|
| Personal
Computers |
|
|
|
|
|
|
| None
|
Q |
Q |
Q |
Q |
Q |
43.5 |
| 1
to 4 |
208 |
28 |
845 |
7 |
4.1 |
43.5 |
| 5
to 9 |
206 |
28 |
943 |
8 |
4.6 |
25.5 |
| 10
to 19 |
139 |
19 |
1,007 |
8 |
7.3 |
12.5 |
| 20
to 49 |
88 |
12 |
1,313 |
11 |
14.9 |
21.5 |
| 50
to 99 |
40 |
5 |
1,247 |
10 |
30.9 |
17.5 |
| 100
to 249 |
29 |
4 |
2,069 |
17 |
71.4 |
19.5 |
| 250
or More |
22 |
3 |
4,571 |
38 |
212.1 |
19.5 |
| |
|
|
|
|
|
|
| Photocopiers |
|
|
|
|
|
|
| None
|
91 |
12 |
801 |
7 |
8.8 |
39.5 |
| One
|
342 |
46 |
1,566 |
13 |
4.6 |
26.5 |
| 2
to 4 |
210 |
28 |
2,373 |
20 |
11.3 |
23.5 |
| 5
to 9 |
52 |
7 |
1,301 |
11 |
25.1 |
12.5 |
| 10
or More |
43 |
6 |
6,003 |
50 |
139.9 |
19.5 |
| |
|
|
|
|
|
|
| Other
Electronic Equipment (more than one may apply) |
|
|
|
|
|
|
| Laser
Printers |
630 |
85 |
11,497 |
95 |
18.2 |
24.5 |
| FAX
Machines |
730 |
99 |
11,979 |
99 |
16.4 |
25.5 |
| |
|
|
|
|
|
|
| Energy-Related
Space Functions (more than one may apply) |
|
|
|
|
|
|
| Commercial
Food Preparation |
17 |
2 |
3,005 |
25 |
175.7 |
24.5 |
| Activities
with Large Amounts of Hot Water |
26 |
3 |
2,360 |
20 |
91.8 |
37.5 |
Q=Data withheld
because the Relative Standard Error (RSE) was greater than 50 percent, or
fewer than 20 buildings were sampled.
Source: Energy Information Administration, 1999 Commercial Buildings Energy
Consumption Survey. Top
Specific questions may be directed to:
Joelle Michaels
joelle.michaels@eia.doe.gov
CBECS Manager
Phone: (202) 586-8952
FAX: (202) 586-0018
Release date: July 24, 2002
Page last modified:
January 16, 2003 11:43 AM
http://www.eia.doe.gov/emeu/cbecs/pba99/office/officeequiptable.html
If you are having any technical problems with this
site, please contact the EIA webmaster at wmaster@eia.doe.gov.
|